01
The requirement
Provide a large circular daylight opening for an occupied nursery environment.
FENNIES NURSERY · WHITTON, LONDON
A bespoke circular rooflight for Fennies Nursery at Whitton Methodist Church, with a 2,000 mm internal diameter and 2,400 mm external diameter.

THE PROJECT
Fennies Real Estate asked Overhead Glazing to design, manufacture and install a circular rooflight for the nursery within the Whitton Methodist Church grounds. The original design allowed for a 2,000 mm external kerb diameter.
Our October 2025 site measure established a larger requirement: 2,000 mm internally and 2,400 mm externally. That change prompted a fresh structural and glazing review before the rooflight was installed in November 2025.

The final unit was coordinated around a 2,000 mm internal diameter and 2,400 mm external diameter.
PROJECT BRIEF
A change in diameter affects more than the aluminium frame. The glass span, loading, handling requirements and manufacturing cost must be reassessed together.
Provide a large circular daylight opening for an occupied nursery environment.
Reassess the glass for the revised diameter using project-specific wind and snow load calculations.
A bespoke unit with a reviewed glass build-up, solar-control specification and laminated inner pane.

PROJECT SPECIFICATION
The revised size required an upgraded glass specification. A SentryGlas® interlayer was selected for the laminated inner pane, and solar-control glazing was recommended for the nursery application.
The aluminium frame was rolled, welded and powder coated to the selected RAL colour. An integral blacked edge to the glass conceals the upstand; it is not a vinyl edge film.
FROM DESIGN TO INSTALLATION
The site survey identified the difference between the initial external kerb assumption and the required opening.
Wind and snow loads were reviewed for the larger unit before the glass build-up was finalised.
The revised frame, glass diameter, solar control and black perimeter detail were coordinated together.
Installation was planned around access to the church site and controlled handling of the large unit.
THE OUTCOME
The finished rooflight brings overhead daylight into the nursery, with the glass and frame developed around the surveyed dimensions rather than the original size assumption.
The key lesson is to distinguish internal opening size from external rooflight or kerb size early. They are different dimensions, and changing either can affect the specification and quotation.
CONTINUE EXPLORING
Explore bespoke round glazing, rolled aluminium frames and glass specification options.
Circular and rectangular solar-control glazing for a nursery renovation.
Understand our recommended glass build-up and overhead safety specification.
PLANNING SOMETHING SIMILAR?
Send the roof plans, sections, approximate dimensions, postcode and any photographs. We can review the geometry and explain the next step.