Home/Projects/Wimbledon, London

TRIANGULAR ROOFLIGHT · WIMBLEDON

An unusual opening.
A precise response.

A bespoke triangular rooflight designed, manufactured and installed for a residential project in Wimbledon, with a thermally broken aluminium frame and carefully planned access.

Bespoke triangular glass rooflight installed at the Wimbledon residential property
WIMBLEDON · BESPOKE TRIANGULAR GLAZING
LOCATIONWimbledon, London
SYSTEMBespoke triangular rooflight
SERVICESite measure, manufacture & installation

THE PROJECT

Made for the opening, down to its angles.

This residential project, with Design United Studio, called for a non-standard triangular rooflight. The glazing needed to suit the roof opening while keeping the frame lines visually restrained.

Overhead Glazing measured the project in September 2025 and installed the rooflight in December 2025. Restricted access and the triangular form made the route to the opening part of the design and installation planning.

Bespoke shaped flat rooflights above the Wimbledon residential property
ARCHITECTURAL CONTEXT

The angular glass follows the geometry of the bespoke roof opening.

PROJECT BRIEF

Resolve shape, performance and access together.

A triangular rooflight cannot be treated as a rectangular unit with one corner removed. Its frame junctions, glass geometry and handling route all need to suit the actual opening.

01

The requirement

Create a triangular glazed feature for a bespoke residential opening.

02

The response

Use a fully thermally broken aluminium frame with externally welded angled junctions.

03

The result

A completed rooflight installed in a single day, following advance planning for restricted access.

Close view of the angled glass perimeter and frame at Wimbledon
Close view of the triangular glass perimeter during the Wimbledon project.

GLASS & FRAME SPECIFICATION

A bespoke shape with a detailed build-up.

The rooflight was supplied with a 34 mm double-glazed unit: heat-soak-tested toughened glass, a warm-edge spacer, an argon-filled cavity and a 13.5 mm toughened, heat-soak-tested laminated inner pane.

Externally welded frame sections resolved the different angles. The important distinction here is the complete thermally broken aluminium frame, coordinated with the shaped glass rather than relying on a generic bonded-frame arrangement.

Glazed unit
34 mm overall
Inner pane
13.5 mm HST toughened laminate
Cavity
Argon filled; warm-edge spacer
Frame
Thermally broken aluminium
Architect
Design United Studio

FROM DESIGN TO INSTALLATION

Plan the route as well as the rooflight.

01

Measure the geometry

The site measure established the non-standard opening before fabrication.

02

Develop the corners

The glass shape and welded frame junctions were coordinated around the triangular outline.

03

Review restricted access

The handling route and positioning sequence were planned in advance.

04

Install the unit

The rooflight was installed in a single day in December 2025.

THE OUTCOME

A distinctive shape with a practical purpose.

The completed glazing introduces overhead daylight while following the geometry of the roof opening. The internal reveal makes the triangular form part of the room’s architecture.

For another shaped opening, the useful starting point is a dimensioned plan and section. That allows the glass, frame, supports and access requirements to be reviewed before a price and specification are agreed.

PLANNING SOMETHING SIMILAR?

Tell us about your roof and the result you want.

Send the roof plans, sections, approximate dimensions, postcode and any photographs. We can review the geometry and explain the next step.